JawChecker™ – measure jaw movement precisely
JawChecker™Functional diagnostics without recording linkage
Contact
Functional diagnostics

JawChecker™

Precisely measure and automatically analyse TMJ function

What it is: The JawChecker measures how the lower jaw moves relative to the upper jaw, using two small sensors attached directly to the teeth, with no recording linkage and no facebow.

What it is for: dental functional diagnostics and therapy, the assessment of temporomandibular joint disorders, the individual programming of the articulator and the provision of the measurement data for CAD/CAM software. It automatically detects jumps in the condylar path such as those caused by disc displacement and reduction.

Operation: The software also understands spoken commands, in many languages. It gives its answers either as text or through audio output.

JawChecker measurement setup: sensors on the jaws, microcontroller, wireless transmission to the computer
Sensors on upper and lower jaw → microcontroller → wirelessly to the computer.
Real measurement

No more recording linkage. Precisely measured.

On the right, a real condylar path plays back with disc displacement on opening and reduction on closing, just as the software shows it. The click sound can be switched on.

Universal capabilities

  • Kinematic hinge axis
  • Condylar paths in 6 planes
  • Disc findings with click detection
  • Bennett angle and path inclination
  • Settings for common articulators
  • Real-time playback
  • Import of older JAWS recordings
  • Link to practice software (VDDS)
  • Data export to CAD/CAM, e.g. exocad
  • Runs on macOS and Windows
  • Ten languages, voice control
Real measurement · sagittal leftt = 0.00 s
Δ mm, anterior (+) · superior (+)
Noextraoral recording linkage or facebow
Affordablewell below conventional recording systems
Precisetwo sensors measure directly on upper and lower jaw
6planes per side: sagittal, frontal, horizontal
The difference

Two sensors instead of a linkage on the head

Conventional electronic recording systems need extraoral components that are attached to and aligned on the patient's head. The JawChecker does without it.

Conventional recording

  • Extraoral recording linkage
  • Time-consuming mounting and alignment on the head
  • Linkage in front of the patient's face
  • High purchase cost

JawChecker™

  • No linkage, no facebow
  • Two small sensors, quickly attached
  • Face unobstructed, natural movement with occlusal surfaces left free
  • Far more affordable, with very precise measurement
Side view of a patient with a small sensor unit on the upper and lower jaw
One sensor unit each on the upper and lower jaw; the circuit board measures just 8.0 × 6.0 mm. No linkage in front of the face.
Measurement

How the JawChecker measures

One sensor sits on the lower jaw, the second on the upper jaw. They are aligned to the occlusal plane and measure acceleration and angular rate. Because the upper jaw is measured as well, the JawChecker records the movement of the lower jaw relative to the upper jaw. The data go to the practice software wirelessly.

  1. Attach the sensors

    Fix the sensor carriers to the upper and lower jaw; the system is detected automatically.

  2. Rest phase

    Hold still for two seconds. The system measures the sampling rate and the zero level of the sensors.

  3. Move on the signal tone

    Opening, protrusion, mediotrusion right and left. Spoken instructions guide through the recording.

  4. Analysis

    Kinematics, condylar paths, joint parameters and disc findings are produced automatically after the recording.

Analysis

What the software calculates from a recording

The measurement data can be analysed and displayed in different ways: as condylar paths in six planes, as an incisal point trace, as velocity and acceleration over time, as articulator settings, and as playback in real time or point by point.

All values apply per side. Graphics and measurement records are linked in the patient menu.

Modern software design: the JAWS software runs on macOS and Windows: a clear, calm interface with numbered work steps from the hinge axis to data transfer, patient search, voice control, spoken instructions and ten languages. Click an image to enlarge it.

Kinematic hinge axis

Position right and left, the basis for all condylar paths.

Condylar paths in 6 planes

Freely performed movements, optionally with the intercondylar connecting line.

Protrusion

Sagittal condylar path inclination from protrusion, evaluated between 0.3 and 7 mm of advancement, mean of several advancements.

Mediotrusion

Bennett angle and path inclination per side.

Incisal point

Path of the incisal point, also for imported recordings.

Velocity and acceleration

As a trace below the curves, with adjustable smoothing.

Disc findings

The click where it happens on the path

The software detects jumps in the condylar path and classifies them as disc displacement or disc reduction. The point is marked in all planes and reported as a finding, read aloud on request.

Displacement

Change of track in cranial direction, space for the disc is lost.

Reduction

Deviation in caudal direction, space for the disc is created.

Reciprocal clicking

The incursive click is always the opposite of the excursive click on the same side.

  • Playback in real time or four times slower – the marker appears only when the curve reaches the point
  • Click sound through the loudspeaker – also for incursive clicks
  • Scanning with mouse or arrow keys – magnifier 1–10×
  • Condylar path inclination only from click-free sections – with a warning whenever clicking is involved
  • Treatment suggestion for the finding – review before adopting and change if needed
AI outlook

Artificial intelligence: the next step

What matters is the short time window immediately before and after a disc displacement or reduction, often accompanied by TMJ clicking. The decelerations, accelerations and angular velocities of the condyles are the actual diagnostic signal here. See and hear what the AI has determined on its own from the measured curve.

Real measurement · Sagittal leftt = 0.00 s
Δ mm, anterior (+) · superior (+)
AI finding

Partial disc displacement with disc dislocation

AI finding

Partial disc displacement with disc reduction

The goal

In future, the JawChecker is to distinguish and interpret functional disorders automatically from their movement patterns, using methods of artificial intelligence.

Reliable training data

Every movement recording is assigned to a confirmed finding, for example from a three-dimensionally evaluated MRI, not from a single slice. Suspected diagnoses have no place there.

Collaboration

Clinics and research groups wishing to contribute are expressly welcome.

Enquire about collaboration

AI-assisted analysis is under development.

Articulator

Settings for semi- and fully adjustable articulators

From the measured joint parameters, the software compiles the values for the most widely used articulators. Hovering over the list immediately shows a picture and the settings of the instrument.

ParameterMovementUnitSide
Sagittal condylar path inclinationProtrusion°right / left
Bennett angleMediotrusion°right / left
Path inclination, mediotrusionMediotrusion°right / left
Hinge axis positionOpening / closingmmright / left

Including Artex, Denar, Panadent and SAM.

In practice

Fits what you already have

Existing recordings remain usable and patients need not be entered twice.

Older recording systems

Import of JAWS recordings from Freecorder BlueFox and Condylocomp LR3, with suitable smoothing for each system.

Practice software

Patient data via the VDDS interface, patient search by number or name.

CAD/CAM

Data transfer to common CAD/CAM software such as exocad.

Operation

Ten languages, voice control, spoken instructions and a tooltip on every control.

History

The fourth generation

The JawChecker is now the fourth practice-ready recording device we have developed. The first, the STRING-LR-Recorder of 1981, was the world’s first practice-ready electronic method for recording jaw movement. Each of these devices was the standard of recording technology in its time and is still ready for use today.

  1. STRING-LR-Recorder

    1981, presented at the congress of the International Academy of Gnathology in Venice. The world’s first practice-ready electronic recording method.

  2. Condylocomp LR3

    Electronic recording of the condylar paths.

  3. Freecorder BlueFox

    Recordings still usable in the software today.

  4. JawChecker™

    Two small sensors, no more recording linkage.

Training

JawChecker training courses

Course leader: the inventor of the JawChecker, Dr. Dr. Rolf Klett, Würzburg, physicist and experienced practising dentist, specialist in functional diagnostics and therapy certified by the DGFDT (German Society for Functional Diagnostics and Therapy) of temporomandibular joint disorders, with decades of teaching courses worldwide.

Dates will be announced.

If you are interested in a course or an information event, please leave your contact details (name, practice, phone or e-mail). We will let you know as soon as the dates are set.

Register interest

Contact

Dentron GmbH

Would you like to know more about the JawChecker? Request further information material. Please include your contact details.

Request information

Company
Dentron GmbH
Address
Eduard-Buchner-Straße 8
D-97204 Höchberg
Phone
+49 171 3808800
E-Mail
info@dentron.com
Web
www.dentron.de